NOTICE OF PUBLIC HEARING
The Dearborn County Regional Sewer District will conduct a public hearing on Thursday, November 19, 2009, at 5:00 p.m. to consider adoption of the following ordinance. The hearing will be held on the Commissioners Room of the Dearborn County Administration Building at 215B West High Street, Lawrenceburg, Indiana.
DEARBORN COUNTY REGIONAL SEWER DISTRICT ORDINANCE 2009-2
An Ordinance adopting a Code of Regulations by the Dearborn County Regional Sewer District (“the District’); WHEREAS, the District is in need of a Code of Regulations for the following purposes: (1) Protect and preserve the works, improvements, and properties owned or controlled by the district, prescribe the manner of use by any person, and preserve order in and adjacent to the works. (2) Prescribe the manner: (A) in which ditches, sewers, pipelines, or other works should be adjusted to or connected with the works of th e district; and
(B) of waste disposal in the district. (3) Prescribe the permissible uses of the water supply and the manner of distribution and prevent
the pollution or unnecessary waste of the water supply. (4) Prohibit or regulate the discharge into the
sewers of the district of liquid or solid waste detrimental to the works and improvements.
NOW, THEREFORE, BE IT ORDAINED BY the District that the following Code of Regulations
are hereby adopted:
RULES AND REGULATIONS
General Provisions
50.001 Definitions
50.002 Depositing objectionable waste prohibited
50.003 Discharging storm water, unpolluted waters and the like
50.004 Depositing wastewater in unsanitary manner within Regional Sewer District
50.005 Discharge of untreated sewage or other polluted wastes to natural outlets
50.006 Privies, septic tanks and other facilities.
50.007 Owner’s responsibility to install suitable toilet facilities.

50.008 Tampering with or damaging Regional Sewer District equipment
50.009 Right of entry for purpose of inspection; indemnification; easements on private property
50.010 Appeal procedure Private Sewage Disposal System
50.025 Connecting building sewer to private sewage disposal
50.031 Noninterference with additional requirements
Building Sewers and Connections
50.045 Connection permit required
50.046 Building sewer permits; permit and inspection fee
50.047 Costs and expenses of installation and connection of building sewer; indemnification
50.048 Separate building sewer provided for every building
50.049 Use of old building sewers with new buildings
50.050 Size, slope and alignment; conformance to building and plumbing code or other applicable regulations
50.051 Elevation of building sewers
50.052 Sources of surface runoff or groundwater
50.053 Connection of building sewer into public sewer, conformance
50.054 Inspection of connection to public sewer
50.055 Excavations
Use of Public Sewers
50.065 Prohibited discharges to public sewer
50.066 Pretreatment, equalization of waste flows
50.067 Preliminary treatment facilities
50.068 Control manholes; measurements, tests and analyses
50.069 Industrial wastes; special agreement
50.070 Discharge of waters from air conditions, cooling, condensing systems or swimming pools.
Pretreatment Requirements
50.080 Compliance with rules and regulations
50.081 Pretreatment or control facilities
50.082 Pretreatment of waters polluted with insoluble oils, grease or suspended solids
50.083 Users to supply information on sewage flow and characteristics
50.084 Determination of strength of sewage through sampling and analysis
50.085 Grease, oil and sand interceptors
50.086 Accidental discharges; notification to Regional Sewer District
50.087 Compliance with state or federal requirements
GENERAL PROVISIONS
§50.001 DEFINITIONS.
For the purpose of this Code, the following definitions shall apply unless the context clearly indicates or requires a different meaning.
BIOCHEMICAL OXYGEN DEMAND (or BOD).
The quantity of oxygen expressed in mg/l utilized in the biochemical oxidation of organic matter under standard laboratory procedures with nitrification inhibition in five at 20°C.
BUILDING DRAIN. That part of the lowest horizontal piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of a building and conveys it to the building sewer beginning five feet outside the building wall.
(1) SANITARY BUILDING DRAIN. A building drain which conveys sanitary or industrial sewage only.
(2) STORM BUILDING DRAIN. A building drain which conveys storm water or other clearwater drainage, but no wastewater.
BUILDING SEWER. The extension from the building drain to the public sewer or other place of disposal. (Also called house connection.)
(1) SANITARY BUILDING SEWER. A building sewer which conveys sanitary or industrial sewage only.
(2) STORM BUILDING SEWER. A building sewer which conveys storm-waste or other clearwater drainage, but no sanitary or industrial sewage.
CODE. The Code of Regulations of the Regional Sewer District.
COMBINED SEWER. A sewer intended to receive both wastewater and storm or surface water.
COMPATIBLE POLLUTANT. Biochemical oxygen demand, suspended solids, pH and fecal coliform bacteria, plus additional pollutants identified in the NPDES permit if the treatment works was designed to treat such pollutants and in fact does remove such pollutants to a substantial degree.The term substantial degree is not subject to precise definition, but generally contemplates removals in the order of 80% or greater. Minor incidental removals in the order of 10% to 30% are not considered substantial.
Examples of the additional pollutants which may be considered compatible include:
(1) Chemical oxygen demand,
(2) Total organic carbon,
(3) Phosphorus and phosphorus compounds,
(4) Nitrogen and nitrogen compounds, and
(5) Fats, oils and greases of animal or vegetable origin (except as prohibited where these materials would interfere with the operation of
the treatment works).
DIRECTOR OR REGIONAL SEWER DISTRICT.
The Director of Sewers of the Regional Sewer District, or his or her authorized deputy, agent or representative.
DISTRICT. Dearborn County’s unincorporated areas currently unserved by a municipal provider or by the current boundaries of the South Dearborn Regional Sewer District.
EASEMENT. An acquired legal right for the specific use of land owned by others.
FECAL COLIFORM. Any of a number of organisms common to the intestinal tract of man and animals, whose presence in sanitary sewage is an indicator of pollution.
FLOATABLE OIL. Oil, fat or grease in a physical state such that will separate by gravity from wastewater by treatment in a pretreatment facility approved by the Regional Sewer District.
GARBAGE. Solid wastes from the domestic and commercial preparation, cooking and dispensing of food, and from the handling, storage
and sale of produce.
INCOMPATIBLE POLLUTANT. Any pollutant that is not defined as a compatible pollutant, including non-biodegradable dissolved solids.
INDUSTRIAL WASTES. The liquid wastes from industrial manufacturing processes, trade or business as distinct from employee wastes or wastes from sanitary conveniences.
iNFILTRATION. The water entering a sewer system, (including building drains and sewers), from the ground, through defects in the system such as, but not limited to, defective pipes, pipe joints, connections or manhole walls. (Infiltration does not include and is distinguished from inflow.)
INFILTRATION/INFLOW. The total quantity of water from both infiltration and inflow without distinguishing the source.
INFLOW.The water discharge into a sewer system, including building drains and sewers, from such sources as, but not limited to, roof leaders, cellar, yard and area drains, foundation drains, unpolluted cooling water discharges, drains from springs and swampy areas, manhole covers, cross connections from storm sewers and combined sewers, catch basins, storm waters, surface run-off, street wash
waters or drainage. (Inflow does not include, and is distinguished from, infiltration.)
INSPECTOR. The person or persons duly authorized by the Regional Sewer District, through its Common Council, to inspect and
approve the installation of building sewers and their connection to the public sewer system.
MAJOR CONTRIBUTING INDUSTRY. AN INDUSTRY
THAT:
(1) Has a flow of 50,000 gallons or more per average work day;
(2) Has a flow greater than 5% of the flow carried by the Regional Sewer District system receiving the waste;
(3) Has in its waste a toxic pollutant in toxic amounts as defined in standards issued under
33 USC 1317(a); or
(4) Has a significant impact, either single or in combination with other contributing industries, on a treatment works or on the quality of effluent from that treatment works.
NPDES PERMIT. A permit issued under the National Pollutant Discharge Elimination System for discharge of wastewaters to the navigable waters of the United States pursuant to 33 USC 1342.
NATURAL OUTLET. Any outlet, including storm sewers and combined sewer overflows, into a watercourse, pond, ditch, lake or other
body of surface or groundwater.
NH3N. The same as Ammonia Nitrogen measured as Nitrogen. The laboratory determinations shall be made in accordance with procedures
set forth in “Standard Methods” as defined in the definition of SLUG.
NORMAL DOMESTIC SEWAGE. The same meaning as defined in § 50.100.
P or PHOSPHOROUS. The chemical element Phosphorous pH. The reciprocal of the logarithm of the hydrogen ion concentration. The concentration is the weight of hydrogen ions in grams per liter of solution.
PERSON. Any individual, firm, company, association, society, corporation, group or other entity.
PRETREATMENT. The treatment of industrial sewage from privately owned industrial sources prior to introduction into a public treatment works.
PRIVATE SEWER. A sewer which is not owned by a public authority.
PROPERLY SHREDDED GARBAGE. The wastes from the preparation, cooking and dispensing of food that has been shredded to such
a degree that all particles will be carried freely under the flow conditions normally prevailing in public sewers, with no particle greater 1/2 inch in any dimension.
PUBLIC SEWER. A sewer which is owned and controlled by the public authority and will consist of the following increments:
(1) COLLECTOR SEWER. A sewer whose primary purpose is to collect wastewaters from individual point source discharges.
(2) FORCE MAIN. A pipe in which wastewater is carried under pressure.
(3) PUMPING STATION. A station positioned in the public sewer system at which wastewater is pumped to a higher level.
REGIONAL SEWER DISTRICT. The Dearborn County Regional Sewer District as forms by Order of the Indiana Department of Environmental Management on November 17, 2003 and governed by its Board of Directors.
SANITARY SEWER. A sewer which carries sanitary and industrial wastes and to which storm, surface and ground water are not intentionally admitted.
SEWAGE. The combination of liquid and water-carried wastes from residences, commercial buildings, industrial plants and institutions,
(including polluted cooling water). The three most commonly types of sewage are:
(1) COMBINED SEWAGE. Wastes including sanitary sewage, industrial sewage, storm water, infiltration and inflow carried to the wastewater treatment facilities by a combined sewer.
(2) INDUSTRIAL SEWAGE. A combination of liquid and water-carried wastes, discharged from any industrial establishment, and resulting from any trade or process carried on in that establishment (this shall include the wastes from pretreatment facilities and polluted cooling water).
(3) SANITARY SEWAGE. The combination of liquid and water-carried wastes discharged from toilets and other sanitary plumbing facilities.
SEWAGE WORKS. The structures, equipment and processes to collect, transport and treat domestic and industrial wastes and dispose of
the effluent and accumulated residual solids.
SEWER. A pipe or conduit for carrying sewage.
SLUG. Any discharge of water or wastewater which in concentration of any given constituent or in quantity of flow exceeds for any period of duration longer than ten minutes more than three times the average 24 hours concentration of flows during normal operation and shall
adversely affect the collection system.
STANDARD METHODS. The laboratory procedures set forth in the latest edition, at the time of analysis, of “Standard Methods for the
Examination of Water Wastewater” prepared and published jointly by the American Public Health Association, the American Water Works Association and the Water Pollution Control Federation.
STORM SEWER. A sewer for conveying water, ground water or unpolluted water from any source and to which sanitary and/or industrial
wastes are not intentionally admitted.
SUSPENDED SOLIDS. Solids that either float on the surface of, or are in suspension in, water, sewage or other liquids and which are
removable by laboratory filtering under standard laboratory procedure.
TOTAL SOLIDS. The sum of suspended and dissolved solids.
TOXIC AMOUNT. Concentrations of any pollutant or combination of pollutants, which upon exposure to or assimilation into any organism will cause adverse effects, such as cancer, genetic mutations and physiological manifestations, as defined in standards issued pursuant to 33 USC 13 17(a).
UNPOLLUTED WATER. Water of quality equal to or better than the effluent criteria in effect, or water that would not cause violation of receiving water quality standards and would not be benefited by discharge to the sanitary sewers and wastewater treatment facilities provided.
VOLATILE ORGANIC MATTER. The material in the sewage solids transformed to gases or vapors when heated at 55°C for 15 to 20 minutes.
WATERCOURSE. A natural or artificial channel for the passage of water either continuously or intermittently.
§ 50.002 DEPOSITING OBJECTIONABLE WASTE PROHIBITED.
It shall be unlawful for any person to place, deposit or permit to be deposited in any unsanitary manner on public or private property within
the Regional Sewer District or in any area under the jurisdiction of the Regional Sewer District any human or animal excrement,garbage or other objectionable waste.
§ 50.003 DISCHARGING STORMWATER, UNPOLLUTED WATERS AND THE LIKE.
(A) No person shall discharge or cause to be discharged to any sanitary sewer, either directly or indirectly, storm waters, surface water, or
unpolluted industrial process water. The Regional Sewer District shall require the removal of unpolluted waters from any wastewater collection or treatment facility.
(B) Storm water, surface water, ground water, roof run-off, subsurface drainage, cooling water, unpolluted water or unpolluted industrial process water may be admitted to storm sewers which have adequate capacity for their accommodation. NO person shall uses such
sewers, however, without the specific written permission of the Regional Sewer District. No new connection shall be made to any sanitary
or storm sewer unless there is capacity available in all downstream sewers, lift stations, force mains and the sewage treatment plant,
including capacity for BOD and suspended solids.
§ 50.004 DEPOSITING WASTEWATER IN UNSANITARY MANNER WITHIN REGIONAL SEWER DISTRICT.
No person shall place, deposit or permit to be deposited in any unsanitary manner on public or private property within the jurisdiction of the Regional Sewer District any wastewater or other polluted waters except where suitable treatment has been provided in accordance with provisions of this Code and the NPDES permit.
§ 50.005 DISCHARGE OF UNTREATED SEWAGE OR OTHER POLLUTED WASTES TO NATURAL OUTLETS.
No person shall discharge or cause to be discharged to any natural outlet any wastewater or other polluted waters except where suitable treatment has been provided in accordance with provisions of this Code and the NPDES permit.
§ 50.006 PRIVIES, SEPTIC TANKS AND OTHER FACILITIES.
Except as hereinafter provided, it shall be unlawful to construct or maintain any privy, privy vault, septic tank, cesspool or other facility intended or used for the disposal of sewage.
§ 50.007 OWNER’S RESPONSIBILITY TO INSTALL SUITABLE TOILET FACILITIES.
The owner of all houses, buildings or properties used for human occupancy, employment, recreation or other purposes, which is not connected to an approved sanitary sewage disposal system, situated within the Regional Sewer District and abutting on any street, alley or right-of-way in which there is not located a public sanitary sewer of the Regional Sewer District is required at his or her expense to install suitable toilet facilities therein, and to connect such facilities directly with the proper public sewer in accordance with the provisions of this Code, within 90 days after date of official notice to do so, provided that the public sewer is within 300 feet of the property line. Within the District, where public sewers are available and located within 300 feet of a property owner’s property line, the owners of all new
dwellings or buildings used for human occupancy, employment, recreation or other purposes, shall install, at their expense, such facilities
necessary to connect to the sanitary sewer of the District. As a condition of connection to a public sewer, the owner(s) shall grant a right of access easement to the building sewer to the Regional Sewer District for the purpose of repair and inspection.
§ 50.008 TAMPERING WITH OR DAMAGING REGIONAL SEWER DISTRICT EQUIPMENT.
No unauthorized person shall maliciously, willfully or negligently break, damage, uncover, deface or tamper with any structure, appurtenance or equipment which is a part of the Regional Sewer District sewage works. Any person violating this provision shall be subject to immediate arrest under charge of disorderly conduct.
§ 50.009 RIGHT OF ENTRY FOR PURPOSE OF INSPECTION; INDEMNIFICATIONS; EASEMENTS ON PRIVATE PROPERTY.
(A) The Director of the Regional Sewer District, Inspector and other duly authorized employees and/or agents of the Regional Sewer District bearing proper credentials and identification shall be permitted to enter all properties for the purpose of inspection, observation, measurement, sampling and testing in accordance with the provisions of this Code. The Director of the Regional Sewer District or his or her representative of this Code. The Director of the Regional Sewer District or his or her representative shall have no authority to inquire into any processes including metallurgical, chemical, oil, refining, ceramic, paper or other industries beyond that point having a direct bearing on the kind and source of discharge to the sewers, waterways or facilities for waste treatment.
(B) While performing the necessary work on private properties referred to in division (A) above, the Director of the Regional Sewer District or duly authorized employees and/or agents of the Regional Sewer District shall observe all safety rules applicable to the premises established by the company, and the company shall be held harmless for injury or death to the Regional Sewer District employees
and/or agents, and the Regional Sewer District employees and against liability claims and demands for personal injury or property damage asserted against the company and growing out of the gauging and sampling operations, except as such may be caused by negligence or failure of the company to maintain safe conditions as required in § 50.068(B).
(C) The Director of the Regional Sewer District and other duly authorized employees and/or agents of the Regional Sewer District bearing proper credentials and identification shall be permitted to enter all private properties through which the Regional Sewer District holds a duly negotiated easement for the purpose of, but not limited to, inspection, observation, measurement, sampling, repair and maintenance of any portion of the sewage works lying within that easement. All entry and subsequent work, if any, on the easement, shall be done in full accordance with the terms of the duly negotiated easement pertaining to the private property
involved.
§ 50.010 APPEAL PROCEDURE
The rules and regulations promulgated by the Regional Sewer District, shall, among other things, provide for an appeal procedure whereby a user shall have the right to appeal a decision of the Director of the Regional Sewer District concerning sewage system of the
Board of the Regional Sewer District may be appealed to a court of competent jurisdiction under the appeal procedures provided for in the
Indiana Administrative Adjudication Act.
PRIVATE SEWAGE DISPOSAL SYSTEM
§ 50.025 CONNECTING BUILDING SEWER TO PRIVATE SEWAGE DISPOSAL.
Where a public sanitary sewer is not availableunder the provisions of § 50.006(B), the building sewer shall be connected to a private sewage disposal system complying with the provisions of this subCode, the building sewer shall be connected to a private sewer disposal system complying with the provisions of the Code of Ordinances of Dearborn County and the State Board of Health.
§ 50.031 NONINTERFERENCE WITH ADDITIONAL REQUIREMENTS
No statement contained in this Code shall be construed to interfere with nay additional requirements that may be imposed by the
Dearborn County Health Officer.
BUILDING SEWERS AND CONNECTIONS
§ 50.045 CONNECTION PERMIT REQUIRED.
No unauthorized person shall uncover, make any connections with or opening into, alter or disturb any public sewer or appurtenance
thereof without first obtaining a written permit from the Regional Sewer District.
§ 50.046 BUILDING SEWER PERMITS; PERMIT
AND INSPECTION FEE.
(A) (1) There shall be two classes of building
sewer permits:
(a) For residential and commercial service,
and
(b) For service to establishments producing
industrial wastes.
(2) In either case, the owner or his or her agent
shall make application on a special form furnished
by the Regional Sewer District. The permit
application shall be supplemented by any
plans, specifications or other information considered
pertinent in the judgment of the
Inspector.
(B) A permit and inspection fee of $________
for residential or commercial building sewer
permit and $_________ for an industrial building
sewer permit shall be paid to the Regional
Sewer District at the time the application is
filed. The inspection shall take place during
normal regular working hours.
§ 50.047 COSTS AND EXPENSES OF INSTALLATION
AND CONNECTION OF BUILDING
SEWER, INDEMNIFICATION.
All costs and expenses incident to the installation
and connection of the building sewer
shall be borne by the owner(s). The owner(s)
shall indemnify the Regional Sewer District
from any loss or damage that may directly or
indirectly be occasioned by the installation of
the building sewer.
§ 50.048 SEPARATE BUILDING SEWER PROVIDED
FOR EVERY BUILDING.
A separate and independent building sewer
shall be provided for every building; except
where one building stands at the rear of another
on an interior lot and no private sewer is
available or can be constructed to the rear
building through an adjoining alley, courtyard
or driveway, the building sewer from the front
building may be extended to the rear building
and the whole considered as one building
sewer.
§ 50.049 USE OF OLD BUILDING SEWERS
WITH NEW BUILDINGS.
Old building sewers may be used in connection
with new buildings only when they are
found, on examination and test by the
Inspector, to meet all requirements of this
Code.
§ 50.050 SIZE, SLOPE AND ALIGNMENT; CONFORMANCE
TO BUILDING AND PLUMBING
CODE OR OTHER APPLICABLE REGULATIONS.
The size, slope, alignment, materials of construction
of a building sewer and the methods
to be used in excavating, placing of the pipe,
jointing, testing, and backfilling the trench shall
all conform to the requirements of the Code of
Ordinances of Dearborn County and/or its rules
and regulations or other applicable rules and
regulations of the Regional Sewer District. In
the absence of code provisions or in amplification
thereof, the materials and procedures set
forth in appropriate specifications of the
A.S.T.M. and S.P.C.F. Manual of Practice No. FD-
9 shall apply.
§ 50.051 ELEVATION OF BUILDING SEWERS.
Whenever possible, the building sewer shall
be brought to the building at an elevation below
the basement floor. In all buildings in which any
building drain is too low to permit gravity flow
to the public sewer, sanitary sewer carried by
such building drain shall be lifted by an
approved means and discharged to the building
sewer.
§ 50.052 SOURCES OF SURFACE RUNOFF OR
GROUNDWATER.
No person(s) shall make connection of roof
downspouts, exterior foundation drains,
areaway drains or other sources of surface
runoff or ground water to a building sewer or
building drain which in turn is connected
directly or indirectly to a public sanitary sewer.
§ 50.053 CONNECTION OF BUILDING SEWER
INTO PUBLIC SEWER; CONFORMANCE.
The connection of the building sewer into the
public sewer shall conform to the requirements
of the Code or Ordinances of Dearborn County
and/or its rules and regulations or other applicable
rules and regulations of the Regional
Sewer District or the procedures set forth in
appropriate specifications of the A.S.T.M. and
the S.P.C.F. Manual of Practice in No. FD-9. All
such connections shall be made gas tight and
water tight. Any deviation from the prescribed
procedures and materials must be approved by
the Director of the Regional Sewer District
before installations.
§ 50.054 INSPECTION OF CONNECTION TO
PUBLIC SEWER.
The applicant for the building sewer permit
shall notify the Inspector when the building
sewer is ready for inspection and connection to
the public sewer. The connection and testing
shall be made under the supervision of the
Inspector or his or her representative. The
applicant shall provide access to all structures
(and areas of structures) to the Inspector for
the purpose of establishing compliance with
this Code.
§ 50.055 EXCAVATIONS.
All excavations for building sewer installation
shall be adequately guarded with barricades
and lights so as to protect the public from hazard.
Streets, sidewalks, parkways and other
public property disturbed in the course of the
work shall be restored in a manner satisfactory
to the Regional Sewer District.
USE OF PUBLIC SEWERS
§ 50.065 PROHIBITED DISCHARGES TO PUBLIC
SEWER.
No person shall discharge or cause to be discharged
any of the following described waters
or wastes to any public sewers:
(A) Any gasoline, benzene, naphtha, fuel oil or
other flammable or explosive liquid, solid or
gas.
(B) Any waters or wastes containing toxic (as
described in Section 307A of the Clean Water
Act) or poisonous solids, liquids or gases in
sufficient quantity, either singly or by interaction
with other wastes, to injure or interfere with
any sewage treatment process, constitute a
hazard to humans or animals, create a pubic
nuisance, or create any hazard in the receiving
waters of the sewage treatment plant.
(C) Any waters or wastes having a pH lower
than 5.5 or having any other corrosive property
capable of causing damage or hazard to structures,
equipment and personnel of the sewage
works or interfere with any treatment process.
(D) Solid or viscous substances in quantities
or of such size capable of causing obstruction
to the flow in sewers or other interference with
the proper operation of the sewage works such
as, but not limited to, ashes, cinders, sand,
mud, straw, shavings, metal, glass, rags, feathers,
tar, plastics, wood, unground garbage,
whole blood, paunch manure, hair and fleshings,
entrails, paper, dishes, cups, milk containers
and the like, either whole or ground by
garbage grinders.
(E) Any waters or wastes containing phenols
or other taste or order producing substances,
in such concentrations exceeding limits which
may be established by the Director of the
Regional Sewer District as necessary, after
treatment of the composite sewage, to meet the
requirements of the state, federal or other public
agencies of jurisdiction of such discharge to
the receiving waters.
(F) Any radioactive wastes or isotopes of such
half-life or concentration as may exceed limits
established by the Director of The Regional
Sewer District in compliance with applicable
state or federal regulations.
(G) Any waters or wastes having pH in excess
of 9.5.
(H) Materials which exert or cause:
(1) Unusual concentrations of inert suspended
solids (such as, but not limited to, Fullers earth,
lime slurries, and lime residues) or of dissolved
solids (such as, but not limited to, sodium chloride
and sodium sulfate).
(2) Excessive discoloration (such as, but not
limited to, dye wastes and vegetable tanning
solutions).
(3) Unusual BOD, chemical oxygen demand or
chlorine requirements in such quantities as to
constitute a significant load on the sewage
treatment works.
(4) Unusual volume of flow or concentration of
wastes constituting “slugs” as defined in §
50.001.
(1) Waters or wastes containing substances
which are not amendable to treatment or reduction
by the sewage treatment processes
employed, or are amendable to treatment only
to such degree that the sewage treatment effluent
cannot meet the requirements of other
agencies having jurisdiction over discharge to
the receiving waters.
§ 50.066 PRETREATMENT, EQUALIZATION OF
WASTE FLOWS.
(A) If any waters or wastes are discharged, or
are proposed to be discharged, to the public
sewers, which waters contain the substances
or possess the characteristics enumerated in §
50.065, and which in judgment of the Director of
the Regional Sewer District may have a deleterious
effect upon the sewage works, processes,
equipment or receiving waters, or which otherwise
create a hazard to life or constitute a public
nuisance, the Director of the Regional Sewer
District may:
(1) Require new industries (or other large
users) or industries (or other large users) with
significant increases in discharges to submit
information on wastewater quantities and characteristics
and obtain prior approval for discharges.
(2) Reject the wastes in whole or in part for
any reason deemed appropriate by the
Regional Sewer District,
(3) Require pretreatment of such wastes to
within the limits of normal sewage as defined,
(4) Require control or flow equalization of
such wastes so as to avoid any “slug” loads or
excessive loads that may be harmful to the
treatment works, or
(5) Require payment of a surcharge on any
excessive flows or loadings discharged to the
treatment works to cover the additional costs of
having capacity for and treating such wastes.
(B) If the Director of the Regional Sewer
District permits the pretreatment or equalization
of waste flows, the design and installation
of the plant and equipment shall be subject to
the review and approval of the Director of the
Regional Sewer District and subject to the
requirements of all applicable codes, ordinances
and laws.
§ 50.067 PRELIMINARY TREATMENT FACILITIES.
Where preliminary treatment or flow-equalizing
facilities are provided for any waters or
wastes, they shall be maintained continuously
in satisfactory and effective operation by the
owner at his or her expense.
§ 50.068 CONTROL MANHOLE; MEASUREMENTS,
TESTS AND ANALYSES.
(A) When required by the Director of the
Regional Sewer District, the owner of any property
services by a building sewer carrying
industrial wastes shall install a suitable control
manhole together with such necessary meters
and other appurtenances in the building sewer
to facilitate observation, sampling and safely
located, and shall be constructed in accordance
with plans approved by the Director of
the Regional Sewer District. The manhole shall
be installed by the owner at his or her expense
and shall be maintained so as to be safe and
accessible at all times. Agents of the Regional
Sewer District, the state water pollution control
agencies and the U.S. Environmental
Protection Agency shall be permitted to enter
all properties for the purpose of inspection,
observation, measurement, sampling and testing.
(B) All measurements, tests and analyses of
the characteristics of waters and wastes to
which reference is made in this Code shall be
determined in accordance with the latest edition
of “Standard Methods of the Examination
of Water and Wastewater,” published by the
American Public Health Association and shall
be determined at the control manhole provided,
or upon suitable samples taken at the control
manhole, except for applications for
NPDES permits and report thereof which shall
be conducted in accordance with rules and
regulations adopted by the USEPA (40 CFR
136). In the event that no special manhole has
been required, the control manhole shall be
considered to be the nearest downstream manhole
in the public sewer to the point at which
the building sewer is connected. Sampling
shall be carried out by customarily accepted
methods to reflect the effect of constituents
upon the sewage works and to determine the
existence of hazards to life, limb and property.
The particular analyses involved will determine
whether a 24 hour composite of all outfalls of a
premises is appropriate or whether a grab
sample or samples should be taken. Normally,
but not always, BOD and suspended solids
analyses are obtained from 24 hour composites
of all outfalls, whereas pH’s are determined
from periodic grab samples.
§ 50.069 INDUSTRIAL WASTES; SPECIAL
AGREEMENT.
No statement contained in this Code shall be
construed as preventing any special agreement
or arrangement between the Regional
Sewer District and any industrial concern
whereby an industrial waste of unusual
strength or character may be accepted by the
Regional Sewer District for treatment, subject
to payment therefore, by the industrial concern,
at such rates as are compatible with §§
50.100 et seq.
§ 50.070 DISCHARGE OF WATERS FROM AIR
CONDITIONERS, COOLING, CONDENSING
SYSTEMS OR SWIMMING POOLS.
Unpolluted water from air conditioners, cooling,
condensing systems or swimming pools
shall be discharged to a storm water, where it
is available, or to a combined sewer approved
by the Regional Sewer District. Where a storm
sewer is not available, discharge may be to a
natural outlet approved by the Regional Sewer
District and by the state. Where a storm sewer,
combined sewer or natural sewer is not available,
such unpolluted water may be discharged
to a sanitary sewer pending written approval
by the Regional Sewer District.
PRETREATMENT REQUIREMENTS
§ 50.080 COMPLIANCE WITH RULES AND
REGULATIONS.
Pretreatment of industrial wastes from major
contributing industries prior to discharge to
the treatment works is required and is subject
to the rules and regulations adopted by the
United States Environmental Protection
Agency (USEPA) (40 CFR 403) and “Guidelines
Establishing Test Procedures for Analysis of
Pollutants” (40 CFR 136), in addition to any
more stringent requirements established by
the Regional Sewer District and any subsequent
state or federal guidelines and rules and
regulations.
§ 50.081 PRETREATMENT OR CONTROL
FACILITIES.
Plans, specifications and any other pertinent
information relating to pretreatment or control
facilities shall be submitted for approval of the
Regional Sewer District, and no construction
of such facilities shall be commenced until
approval in writing is granted. Where such
facilities are provided, they shall be maintained
continuously in satisfactory and effective
operating order by the owner at his or her
expense and shall be subject to periodic
inspection by the Regional Sewer District to
determine that such facilities are being operated
in conformance with applicable federal,
state and local laws and permits. The owner
shall maintain operating records and shall submit
to the Regional Sewer District a monthly
summary report of the character of the influent
and effluent to show the performance of the
treatment facilities and for comparison against
Regional Sewer District monitoring records.
§ 50.082 PRETREATMENT OF WATERS POLLUTED
WITH INSOLUBLE OILS, GREASE OR
SUSPENDED SOLIDS.
Industrial cooling water, which may be polluted
with insoluble oils or grease or suspended,
solids, shall be pretreated for removal of pollutants
and the resultant clear water shall be discharged
in accordance with this Code.
§ 50.083 USERS TO SUPPLY INFORMATION
ON SEWAGE FLOW AND CHARACTERISTICS.
The Regional Sewer District may require
users of the treatment works, other than residential
users, to supply pertinent information
on wastewater flows and characteristics. Such
measurements, tests and analysis shall be
made at the users’ expenses. If made by the
Regional Sewer District, an appropriate charge
may be assessed to the user at the option of he
Regional Sewer District.
§ 50.084 DETERMINATION OF STRENGTH OF
SEWAGE THROUGH SAMPLING AND ANALYSIS.
The strength of wastewaters shall be determined,
for periodic establishment of charges
provided for in this Code from samples taken
at the aforementioned structure at any period
of time and of such duration and in such manner
as the Director of the Regional Sewer
District may elect, or, at any place mutually
agreed upon between the user and the Director
of the Regional Sewer District. Appropriate
charges for sampling and analysis may be
assessed to the user at the option of the
Director of the Regional Sewer District. The
results of routine sampling and analysis by the
user may also be used for determination of
charges after verification by the Director of the
Regional Sewer District.
§ 50.085 GREASE, OIL AND SAND INTERCEPTORS.
Grease, oil and sand interceptors or traps
shall be provided when, in the opinion of the
Director of the Regional Sewer District, they
are necessary for the proper handling of liquid
wastes containing grease in excessive
amounts, or any flammable wastes, sand and
other harmful ingredients, except th at such
interceptors or traps will not be required for
private living quarters or dwelling units. All
interceptors or traps shall be of a type and
capacity approved by the Director of the
Regional Sewer District and shall be located so
as to be readily and easily accessible for cleaning
and inspection. They shall be construed of
impervious materials capable of withstanding
abrupt and extreme changes in temperatures
and shall be of substantial construction, be
gastight, water tight and equipped with easily
removable covers. Where installed, all grease,
oil and sand interceptors or traps shall be
maintained by the owner, at his or her expense,
in continuously efficient operation at all times.
§50.086 ACCIDENTAL DISCHARGES; NOTIFICATION
TO REGIONAL SEWER DISTRICT.
Users of the treatment works shall immediately
notify the Regional Sewer District of any
unusual flows or wastes that are discharged
accidentally or otherwise to the sewer system.
§ 50.087 COMPLIANCE WITH STATE OR FEDERAL
REQUIREMENTS.
All provisions of this Code and limits set
herein shall comply with any applicable state
and/or federal requirements now or projected
to be in effect.
Presented by me to the President of said
Board on this _______ day of
_______________, 2009.
Secretary
Signed and approved by me, as President of
the Dearborn County Regional Sewer District,
on this ______ day of __________________,
2009.
President
ATTEST:
Secretary
C-10-20-JP-2t

5 comments:

My Pretty said...

At least Vera still has a reason to get out of her cold bed in the morning.

http://thesamerowdycrowd.files.wordpress.com/2008/10/gulch.jpg

Chester said...

Who the hell wrote this abomination?

As soon as they pass this as I read it 1) it's illegal to have a septic tank even though the county approved it, 2) you have to hook up to the public sewer no matter how far it is from your house as long as it is within 300 feet of any part of your property, 3) if you don't hook to the public sewer, you have to hook up to a private sewer, apparently no matter how far away it is!!

Oh, and there is no phase in, no requirement for them to have actually provided the sewer, so 90 days after passage you better be hooked up to something - how much sewer do you think they will have built by the end of that 90 days? How far away is your nearest 'private' sewer?

I guess if you can't afford any of the above, you have to board up your house, live in a tent and you are just stuck taking a crap out in the yard. No, wait, according to 50.002 you can't even do that.

Torches and Pitchforks, anybody? The crew that tries to pass this should be tarred and feathered. I'm sick to death of these ignorant, no make that STUPID, arrogant, jackasses.

??? said...

Hidden Valley has sewers run by an equally dishonest and incompetent bunch of development owned thugs.

How is that working out for the local environment?

Are crooked developers and realtors still trying to build more homes and hook them up to VRUC's over-flowing sewers?

??? said...

Why do our local juvenile and spoiled developers, realtors, title attorneys and all their cronies believe the rest of us own them a paycheck by trying to force us to subsidize their development by forcing ALL of us on quickie substandard sewers in order for them to max out their return on the dollar for land they wish to densely develop?

??? said...

Hughes pretty much voted "present" on the forced hook up debate, while voting for or to reappoint each and every member on the DCRSD that are in favor of forced hook ups.

What did it cost him to get narrowly reelected?

Where are Benning and Fox today?

Think about that, some of you more recalcitrant development owned "bo-bo's" on the county council.

Have a great day!